00
0
No products in the cart.

Shopping Cart

Stainless Steel (SS304) Insect Killer 2 feet (Double Choke) | Chronovex

₹5,830.00 ₹8,499.00

SS304 Insect Killer 2 Feet (Double Choke)

Food-grade SS304 stainless 2 ft insect killer — dual-choke ballast

  • Coverage: 100–120 sq m
  • UV Lamp: 15 W actinic × 2
  • Ballast: Dual-choke (extends tube life 30%)
  • Power: 220 V · 50 Hz · 45 W draw
  • Body material: SS304 stainless steel (1.0 mm)
  • HSN: 8543 70 99 · GST invoice · ISO 9001:2015 Noida
  • Warranty: 1 year on UV tubes, 2 years on SS304 body

↓ Full specs, applications & FAQ

❓ Frequently Asked Questions

How long does installation take and who installs it?
About 20–25 minutes per unit (slightly longer than CRCA models because the SS304 chassis is heavier and the IP55 gasket needs proper seating). The ultra-rapid-killer-ss ships with wall-mount template, SS304 fasteners, and ceiling-chain kit. Mount at 1.8–2.2 m above floor, away from competing light sources and never above open food-prep surfaces — FSSAI requires insect killers to be positioned where dead insects cannot fall onto open food. Power up on a 230V/15A switched outlet. For multi-unit pharma / food-processing rollouts, we coordinate certified electricians on a chargeable AMC basis.
Why pay more for SS304 over CRCA when both have powder-coated finish?
Three reasons. (1) Audit compliance: pharma Schedule M, WHO-GMP, and USFDA cGMP require food-contact and food-adjacent equipment to be constructed of non-corrodible, non-flaking material — SS304 is the explicit specification; powder-coated CRCA fails this audit because the coating eventually chips. (2) Wash-down life: SS304 with IP55 sealing survives daily caustic wash-down for 10+ years; CRCA powder-coat starts rusting within 12–18 months in dairy / fish / brewery environments. (3) Sterile zone: SS304 has no porosity for bacterial colonisation — critical in IVF, OT support, and pharma packing.
How is the ultra-rapid-killer-ss different from CRCA insect killers in your range?
The ultra-rapid-killer-ss uses fully welded SS304 (18-8) stainless-steel chassis with electropolished interior, IP55 sealed enclosure, food-grade certification versus powder-coated CRCA on Bluster / Hunter Edge / Killer Expert / Power Killer models. Operating principle (UV-A 365nm + electrocuting grid) is the same, but the chassis material qualifies the unit for pharma and food-processing audits. Catch performance is comparable to equivalent CRCA models; the premium is paid for compliance, wash-down longevity, and audit defensibility — not for higher catch rate.
What is the payback period for a pharma / food-processing buyer?
For pharma and FSSAI/USFDA-audited facilities, the payback is regulatory, not just commercial. A single audit non-conformity for using non-compliant (rusting / powder-coated) insect killers in a GMP zone can trigger CAPA documentation costs of ₹50,000–₹2,00,000 and risk re-inspection delays. The unit price premium of SS304 over CRCA (typically ₹3,000–₹5,000 per unit) is recovered on the first avoided audit observation. Compare also the wash-down longevity: 10-year SS304 life versus 12–18-month CRCA failure cycle.
What HSN, GST rate, and tax-invoice format do you provide?
HSN <strong>8543 70 99</strong> (Electrical machines and apparatus, having individual functions, not specified or included elsewhere in Chapter 85). GST <strong>18%</strong>. Every invoice carries IRN, signed QR (e-invoice as per CBIC mandate for B2B above the prescribed turnover threshold), our GSTIN, and HSN — fully eligible for buyer-side GSTR-2B auto-reconciliation. ITC (Input Tax Credit) is admissible for registered B2B buyers using these units in the course of business. Use our GSTIN for two-way reconciliation.
What warranty do you provide and how do I reach support?
24-month manufacturer warranty on the SS304 chassis (vs 12-month on CRCA models) and 12-month on transformer / ballast components from invoice date. Tubes are consumables (not covered, priced affordably for replacement). Send service requests on WhatsApp <strong>+91 99977-78202</strong> with photo + invoice; we respond within one business day. For bulk buyers (5+ units) we offer optional AMC covering preventive tube replacement, grid cleaning, IP55 gasket inspection, and on-site audit-readiness checks.
(Available)
Estimated delivery:Jun 28 - Jul 02
Quantity
Already purchased? Register your unit Get your warranty activated within 24 hrs — Hinglish helpline available.
Register Now

SKU:ultra-rapid-killer-ss

Categories:All Products, Insect Control, Insect Killers (Zappers)

🦟 SS304 Insect Killer 2 Feet (Double Choke)

Food-grade SS304 stainless 2 ft insect killer — dual-choke ballast

🔎 Overview

SS304 stainless-body 2 ft electric fly killer with dual-choke ballast for tube longevity. Wash-down rated for FSSAI / HACCP food-processing zones. Made in Noida by Chronovex Industries (ISO 9001:2015). Full ITC GST invoice, pan-India dispatch.

📋 Specifications

Coverage100–120 sq m
UV Lamp15 W actinic × 2
BallastDual-choke (extends tube life 30%)
Power220 V · 50 Hz · 45 W draw
Body materialSS304 stainless steel (1.0 mm)
HygieneFSSAI / HACCP wash-down ready
MountWall / chain-hang
HSN8543 70 99
Warranty1 year on UV tubes, 2 years on SS304 body

🏭 Best-fit applications

FSSAI-certified food processing, dairies, meat / poultry plants, pharma packaging, hospital pharmacies

🔧 Logistics & install

Same-day dispatch from Noida. Delhi NCR delivery 1–2 days, metros 3–5, tier-2/3 5–7. Full ITC GST invoice on every order — verified courier and transport partners.

❓ FAQ

Do you provide GST invoice? Yes — full ITC GST invoice on every order, dispatched from Noida.

What is the warranty? 1 year on UV tubes, 2 years on SS304 body.

What is the HSN code? 8543 70 99.

Do you support project orders / bulk? Yes — contact us for 10+ unit pricing and pan-India project rollouts.


Frequently Asked Questions

Find answers to common questions about this product

About 20–25 minutes per unit (slightly longer than CRCA models because the SS304 chassis is heavier and the IP55 gasket needs proper seating). The ultra-rapid-killer-ss ships with wall-mount template, SS304 fasteners, and ceiling-chain kit. Mount at 1.8–2.2 m above floor, away from competing light sources and never above open food-prep surfaces — FSSAI requires insect killers to be positioned where dead insects cannot fall onto open food. Power up on a 230V/15A switched outlet. For multi-unit pharma / food-processing rollouts, we coordinate certified electricians on a chargeable AMC basis.

Three reasons. (1) Audit compliance: pharma Schedule M, WHO-GMP, and USFDA cGMP require food-contact and food-adjacent equipment to be constructed of non-corrodible, non-flaking material — SS304 is the explicit specification; powder-coated CRCA fails this audit because the coating eventually chips. (2) Wash-down life: SS304 with IP55 sealing survives daily caustic wash-down for 10+ years; CRCA powder-coat starts rusting within 12–18 months in dairy / fish / brewery environments. (3) Sterile zone: SS304 has no porosity for bacterial colonisation — critical in IVF, OT support, and pharma packing.

The ultra-rapid-killer-ss uses fully welded SS304 (18-8) stainless-steel chassis with electropolished interior, IP55 sealed enclosure, food-grade certification versus powder-coated CRCA on Bluster / Hunter Edge / Killer Expert / Power Killer models. Operating principle (UV-A 365nm + electrocuting grid) is the same, but the chassis material qualifies the unit for pharma and food-processing audits. Catch performance is comparable to equivalent CRCA models; the premium is paid for compliance, wash-down longevity, and audit defensibility — not for higher catch rate.

For pharma and FSSAI/USFDA-audited facilities, the payback is regulatory, not just commercial. A single audit non-conformity for using non-compliant (rusting / powder-coated) insect killers in a GMP zone can trigger CAPA documentation costs of ₹50,000–₹2,00,000 and risk re-inspection delays. The unit price premium of SS304 over CRCA (typically ₹3,000–₹5,000 per unit) is recovered on the first avoided audit observation. Compare also the wash-down longevity: 10-year SS304 life versus 12–18-month CRCA failure cycle.

HSN 8543 70 99 (Electrical machines and apparatus, having individual functions, not specified or included elsewhere in Chapter 85). GST 18%. Every invoice carries IRN, signed QR (e-invoice as per CBIC mandate for B2B above the prescribed turnover threshold), our GSTIN, and HSN — fully eligible for buyer-side GSTR-2B auto-reconciliation. ITC (Input Tax Credit) is admissible for registered B2B buyers using these units in the course of business. Use our GSTIN for two-way reconciliation.

24-month manufacturer warranty on the SS304 chassis (vs 12-month on CRCA models) and 12-month on transformer / ballast components from invoice date. Tubes are consumables (not covered, priced affordably for replacement). Send service requests on WhatsApp +91 9997778202 with photo + invoice; we respond within one business day. For bulk buyers (5+ units) we offer optional AMC covering preventive tube replacement, grid cleaning, IP55 gasket inspection, and on-site audit-readiness checks.
ChronovexInstall AppFREE×
Install Chronovex App
Tap ShareAdd to Home Screen.
×